English
Leave Your Message
Brief Table of Performance for Commercial Reverse Osmosis Membranes

Membrane

Brief Table of Performance for Commercial Reverse Osmosis Membranes

    Specification:

     

    Membrane Component Classification

     

    Membrane

    Component

    Model

     

    Stable Desali nation Rate

    (%)

     

     

    Average Yield

    Water GPD

    (m³/d)

     

    Operating

    Pressure and

    Applicable Scope

    Test Conditions
    Test

    Pressure

    Test Solution Recovery Rate

    (%)

    psi(Mpa)
     

     

     

     

     

     

     

    Commercial

    swers

    Membrane  Components

    QC-2012-400 92 400(1.52)  

     

     

     

     

     

     

    Extremely low

    pressure operation,

    suitable for

    household water

    purifier and

    commercial water

    purifier

     

    100

    (0.69)

     

    300

     

    50

    QC-3013-800 95 800(3.0)
    QC-3012-300 96 300(1.14)  

     

     

     

    75(0.52)

     

     

     

     

    250

     

     

     

     

    35

    QC-3012-400 96 400(1.52)
    QC-3013-400 96 400(1.52)
    QC-3013-600 96 600(2.30)
    QC-3213-600 96 600(2.30)
    QC-3213-800 96 800(3.0)  

     

    90(0.62)

     

     

    250

     

     

    35

    QC-3413-800 96 800(3.0)
    QC-3413-1000 96 1000(3.8)

    Operating Limit:

    Max. Feed Water SDhe 5
    Max. Operating Pressure: 300psi(2.07MPa)
    PH Range(chemical Cleaning): 2~12
    PH Range(Continuous operation): 3~10
    Free Chlorine Concentration:-------------------------------<0.1ppm
    Max. Feed Water Temperature:----------------------------113°F(45°C)
    Max. Pressure Drop of Single Membrane:--------------15psi(0.1Mpa)