English
Leave Your Message
PVC-U water supply pipe, known for its durability and corrosion resistance

Water Pipe Product

PVC-U water supply pipe, known for its durability and corrosion resistance

light weight, easy handling, low construction intensity, fast progress, can save construction costs:
The density of PVC-U pipe is about 1400kg/m3, which is only 1/5 of cast iron pipe and 1/3 of concrete pipe, and the construction cost can be reduced by 30%-50% compared with traditional pipe.

    Product characteristics:

    1, light weight, easy handling, low construction intensity, fast progress, can save construction costs:
    The density of PVC-U pipe is about 1400kg/m3, which is only 1/5 of cast iron pipe and 1/3 of concrete pipe, and the construction cost can be reduced by 30%-50% compared with traditional pipe.
    2, the fluid resistance is small:
    The wall of PVC-U pipe is smooth, the fluid resistance is small, the roughness coefficient is only 0.009, and the water transfer capacity of PVC-U pipe is 20% higher than that of cast iron pipe of the same diameter, and 40% higher than that of concrete pipe.
    3、Excellent corrosion resistance and drug resistance:
    PVC-U pipe has excellent acid resistance, alkali resistance, corrosion resistance, is not affected by moisture and soil alkali resistance, and does not need any corrosion resistance treatment during pipeline laying.
    4、according to the actual engineering experience, low maintenance costs:
    PVC-U pipe maintenance is simple, does not require expensive and complex tools, according to actual engineering experience, its maintenance cost is only 30% of cast iron pipe or concrete pipe.
    5、High mechanical strength:
    PVC pipe has good water pressure strength, impact strength and other properties, and is suitable for pipe distribution projects under various conditions at room temperature.
    6, with good water tightness:
    PVC-U pipe installation, regardless of the use of bonding or rubber ring connection, has good water tightness.
    7. Anti-biting:
    PVC-U tubing is not a source of nutrients, so it is not subject to erosion by rodents. According to experiments conducted by the National Health Foundation in Michigan, rats will not bite PVC-U pipe.
    8, material health: product health performance in line with GB/T 17219 national standards.
    9. No pollution to water quality:
    PVC-U pipe does not scale, and will not cause secondary pollution to water quality in the process of water transmission.

    PVC-U water pipe parameter list

    (Executive standard: GB/T10002.1-2006, IS04422-1996)

    Product picture Nominal outside diameter (mm) Length m/ branch Enforce standards Wall thickness (mm) Nominal pressure (MPa)
     

     

    p1kdm

     

     

     

     

    p1 (3)8lk

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    p1 (4)k8s

    20

    4

    IS0

    1.5 1.60

    GB

    2.0 2.0
    2.3 2.5

    25

    4

    IS0

    1.5 1.25

    GB

    2.0 1.6
    2.3 2.0
    2.8 2.5

    32

    4

    IS0

    1.6 .00

    GB

    2.0 1.25
    2.4 1.6
    2.9 2.0
    3.6 2.5

    40

    4

    IS0

    1.5 0.63

    IS0

    1.6 0.8

    GB

    2.0 1.0
    2.4 .25
    3.0 1.6
    3.7 2.0
    4.5 2.5

    50

    4

    IS0

    1.6 0.63

    GB

    2.0 0.8
    2.4 1.0
    3.0 1.25
    3.7 1.60
    4.6 2.00
    5.6 2.50

    63

    4

    IS0

    1.6 0.50

    IS0

    1.9 0.60

    GB

    2.0 0.63
    2.5 0.8
    3.0 1.0
    3.8 1.25
    4.7 1.6
    5.8 2.0
    7.1 2.5

    6

    IS0

    1.6 0.50

    IS0

    1.9 0.60

    GB

    2.0 0.63
    2.5 0.8
    3.0 1.0
    3.8 1.25
    4.7 1.6
    5.8 2.0
    7.1 2.5

    PVC-U water pipe parameter list

    (Executive standard: GB/T10002.1-2006, IS04422-1996)

    Product picture Nominal outside diameter (mm) Length m/ branch Enforce standards Wall thickness (mm) Nominal pressure (MPa)
     

     

    p1 (5)3q1

     

     

     

     

    p1 (6)z07

     

     

     

     

     

     

     

    p1 (7)icg

     

     

     

    p1 (8)pbw

     

     

     

     

     

    p1 (9)3af

    75

    4

    IS0

    1.9 0.5

    IS0

    2.2 0.6

    GB

    2.3 0.63
    2.9 0.8
    3.6 1.0
    4.5 1.25
    5.6 1.6
    6.9 2.0
    8.4 2.5

    6

    IS0

    1.9 0.5

    IS0

    2.2 0.6

    GB

    2.3 0.63
    29 0.8
    3.6 1.0
    4.5 1.25
    5.6 1.6
    6.9 2.0
    8.4 2.5

    90

    4

    IS0

    2.2 0.5

    IS0

    2.7 0.6

    GB

    2.8 0.63
    3.5 0.8
    4.3 1.0
    5.4 1.25
    6.7 1.6
    8.2 2.0
    10.1 2.5

    6

    IS0

    2.2 0.5

    IS0

    2.7 0.6

    GB

    2.8 0.63
    3.5 0.8
    4.3 1.0
    5.4 1.25
    6.7 1.6
    8.2 2.0
    10.1 2.5

    110

    6

    GB

    2.7 0.63
    3.4 0.80
    4.2 1.00
    5.3 1.25
    6.6 1.60
    8.1 2.00
    10.0 2.50

    PVC-U water pipe parameter list

    (Executive standard: GB/T10002.1-2006, IS04422-1996)

    Product picture Nominal outside diameter (mm) Length m/ branch Enforce standards Wall thickness (mm) Nominal pressure (MPa)
     

     

    p1 (10)mlg

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    p1 (11)kml
     

     

     

    125

     

     

     

    6

     

     

     

    GB

    3.1 0.63
    3.9 0.80
    4.8 1.00
    6.0 1.25
    7.4 1.60
    9.2 2.00
    11.4 2.50
     

     

     

    140

     

     

     

    6

     

     

     

    GB

    3.5 0.63
    4.3 0.80
    5.4 1.00
    6.7 1.25
    8.3 1.60
    10.3 2.00
    12.7 2.50
     

     

     

    160

     

     

     

    6

     

     

     

    GB

    4.0 0.63
    4.9 0.80
    6.2 1.00
    7.7 1.25
    9.5 1.60
    11.8 2.00
    14.6 2.50
     

     

    180

     

     

    6

     

     

    GB

    4.4 0.63
    5.5 0.80
    6.9 1.00
    8.6 1.25
    10.7 1.60
    13.3 2.00
    16.4 2.50
     

     

     

    200

     

     

     

    6

     

     

     

    GB

    4.9 0.63
    6.2 0.80
    7.7 1.00
    9.6 1.25
    11.9 1.60
    14.7 2.00
    18.2 2.50
     

     

    225

     

     

    6

     

     

    GB

    5.5 0.63
    6.9 0.80
    8.6 1.00
    10.8 1.25
    13.4 1.60
    16.6 2.00
     

     

    250

     

     

    6

     

     

    GB

    6.2 0.63
    7.7 0.80
    9.6 1.00
    11.9 1.25
    14.8 1.60
    18.4 2.00
    280 6 GB 6.9 0.63
    8.6 0.80

    PVC-U water pipe parameter list

    (Executive standard: GB/T10002.1-2006, IS04422-1996)

    Product picture Nominal outside diameter (mm) Length m/ branch Enforce standards Wall thickness (mm) Nominal pressure (MPa)
     

     

    p1 (12)llp

     

     

     

     

    p1 (13)3m2

     

     

     

    p1 (14)c84

    280

    6

    GB

    10.7 1.00
    13.4 1.25
    16.6 1.60
    20.6 2.00

    315

    6

    GB

    7.7 0.63
    9.7 0.80
    12.1 1.00
    15.0 1.25
    18.7 1.60
    23.2 2.00

    355

    6

    GB

    8.7 0.63
    10.9 0.80
    13.6 1.00
    16.9 1.25
    21.1 1.60
    26.1 2.00

    400

    6

    GB

    9.8 0.63
    12.3 0.80
    15.3 1.00
    19.1 1.25
    23.7 1.60
    29.4 2.00

    450

    6

    GB

    11.0 0.63
    13.8 0.80
    17.2 1.00
    21.5 1.25
    26.7 1.60
    33.1 2.00

    500

    6

    GB

    12.3 0.63
    15.3 0.80
    19.1 .00
    23.9 1.25
    29.7 1.60
    36.8 2.00

    560

    6

    GB

    13.7 0.63
    17.2 0.80
    21.4 1.00
    26.7 1.25

    630

    6

    GB

    15.4 0.63
    19.3 0.80
    24.1 1.00
    30.0 1.25

    710

    6

    GB

    17.4 0.63
    21.8 0.80
    27.2 1.00

    800

    6

    GB

    19.6 0.63
    24.5 0.80
    30.6 1.00